Development of procedures for programmable proximity aperture lithography

2013

Abstract Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyvaskyla and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeata…

Nuclear and High Energy Physicsta114business.industryApertureComputer sciencemicrofluidicsScalable Vector GraphicsFaraday cupcomputer.file_formatMeV ion beam lithographyprogrammable proximity aperture lithography (PPAL)symbols.namesakeSoftwareOpticsion-fluencePosition (vector)CalibrationElectronic engineeringsymbolsbusinessInstrumentationLithographycomputerBeam (structure)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

2020

Recent experiments have demonstrated the formation of free-standing Au monolayers by exposing the Au–Ag alloy to electron beam irradiation. Inspired by this discovery, we used semi-empirical effective medium theory simulations to investigate monolayer formation in 30 different binary metal alloys composed of late d-series metals such as Ni, Cu, Pd, Ag, Pt, and Au. In qualitative agreement with the experiment, we find that the beam energy required to dealloy Ag atoms from the Au–Ag alloy is smaller than the energy required to break the dealloyed Au monolayer. Our simulations suggest that a similar method could also be used to form Au monolayers from the Au–Cu alloy and Pt monolayers from Pt–…

010302 applied physicsMaterials scienceAlloyGeneral Physics and AstronomyBinary number02 engineering and technologyengineering.material021001 nanoscience & nanotechnology01 natural sciencesMolecular physicsMetalElectron beam irradiationvisual_art0103 physical sciencesMonolayerengineeringvisual_art.visual_art_medium0210 nano-technologyBeam energyAIP Advances
researchProduct

Fast-beam laser spectroscopy of neutron-rich barium isotopes

1981

Nuclear and High Energy PhysicsMaterials sciencechemistryIsotopechemistry.chemical_elementNeutronBariumBeam laserPhysical and Theoretical ChemistryAtomic physicsCondensed Matter PhysicsSpectroscopyAtomic and Molecular Physics and OpticsHyperfine Interactions
researchProduct

Broad beam transmission data for the shielding of brachytherapy facilities

2008

medicine.medical_specialtyOpticsOncologybusiness.industrymedicine.medical_treatmentElectromagnetic shieldingBrachytherapymedicineRadiology Nuclear Medicine and imagingMedical physicsBeam transmissionbusinessBrachytherapy
researchProduct

Transverse distribution of beam current oscillations of a 14 GHz electron cyclotron resonance ion source

2014

The temporal stability of oxygen ion beams has been studied with the 14 GHz A-ECR at JYFL (University of Jyvaskyla, Department of Physics). A sector Faraday cup was employed to measure the distribution of the beam current oscillations across the beam profile. The spatial and temporal characteristics of two different oscillation “modes” often observed with the JYFL 14 GHz ECRIS are discussed. It was observed that the low frequency oscillations below 200 Hz are distributed almost uniformly. In the high frequency oscillation “mode,” with frequencies >300 Hz at the core of the beam, carrying most of the current, oscillates with smaller amplitude than the peripheral parts of the beam. The result…

Physicsta114Oscillationbeam current oscillationsCyclotronElectric Conductivitytransverse distributionFaraday cupElectronsCyclotronsLower hybrid oscillationPlasma oscillationElectron cyclotron resonancelaw.inventionsymbols.namesakelawUpper hybrid oscillationsymbolsAtomic physicsInstrumentationBeam (structure)Review of Scientific Instruments
researchProduct

Si Donor Incorporation in GaN Nanowires

2015

With increasing interest in GaN based devices, the control and evaluation of doping are becoming more and more important. We have studied the structural and electrical properties of a series of Si-doped GaN nanowires (NWs) grown by molecular beam epitaxy (MBE) with a typical dimension of 2-3 μm in length and 20-200 nm in radius. In particular, high resolution energy dispersive X-ray spectroscopy (EDX) has illustrated a higher Si incorporation in NWs than that in two-dimensional (2D) layers and Si segregation at the edge of the NW with the highest doping. Moreover, direct transport measurements on single NWs have shown a controlled doping with resistivity from 10(2) to 10(-3) Ω·cm, and a car…

Electron mobilityMaterials scienceNanowireBioengineeringNanotechnology02 engineering and technology01 natural sciencesElectrical resistivity and conductivity0103 physical sciencesGeneral Materials ScienceSpectroscopyComputingMilieux_MISCELLANEOUS010302 applied physics[PHYS]Physics [physics]business.industryMechanical EngineeringDopingGeneral ChemistryRadius021001 nanoscience & nanotechnologyCondensed Matter PhysicsOptoelectronicsField-effect transistor0210 nano-technologybusinessMolecular beam epitaxy
researchProduct

Shape coexistence in Hg-178

2019

Lifetime measurements of excited states in Hg-178 have been performed using the Rh-103(Kr-78, p2n) reaction at a beam energy of 354 MeV. The recoil-decay tagging (RDT) technique was applied to select the Hg-178 nuclei and associate the prompt gamma rays with the correlated characteristic ground-state alpha decay. Lifetimes of the four lowest yrast states of Hg-178 have been determined using the recoil distance Doppler-shift (RDDS) method. The experimental data are compared to theoretical predictions with focus on shape coexistence. The results confirm the shift of the deformed prolate structures to higher lying states but also indicate their increasing deformation with decreasing neutron nu…

PhysicsGEManchester Cancer Research Centre3106010308 nuclear & particles physicsYrastResearchInstitutes_Networks_Beacons/mcrcNuclear structureProlate spheroidNuclear Structure01 natural sciences114 Physical sciencesLIFETIMESPLUNGERRecoilSTATESExcited stateNeutron number0103 physical sciencesMERCURYAtomic physics010306 general physicsNuclear ExperimentBeam energy
researchProduct

Diagnostic accuracy of cone-beam CT compared with panoramic images in predicting retromolar canal during extraction of impacted mandibular third mola…

2014

Objectives: The clinical significance of the existence of a retromolar canal and of its neurovascular content is not yet clear.The aim of the present study was to assess the visibility, diameter and course of the mandibular retromolarcanal (MRC) using cone beam computed tomography (CBCT) scan -had been taken for pre-operative radiographic evaluation of impacted mandibular third molars- compared to panoramic radiographs. Study Design: Subjects eligible for study enrollment were those who underwent preoperative CBCT scan for the extraction of impactedmandibular third molars were determined to be extremely close to the mandibular canal on panoramic radiographs. Radiographs were screened for th…

MolarAdultMaleCone beam computed tomographyAdolescentRadiographyMandibular canalDentistryAccessory InnervationOdontologíaMandibleMandibular second molarYoung AdultCone Beam Computed Tomographystomatognathic systemPredictive Value of TestsRadiography PanoramicForamenmedicineHumansGeneral DentistryMandibular AnatomyRetrospective StudiesIntraoperative Carebusiness.industryResearchRetromolar CanalMandibleRetromolar ForamenTooth ImpactedReproducibility of ResultsCone-Beam Computed TomographyMiddle Agedrespiratory systemNeurovascular bundle:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludrespiratory tract diseasesmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASTooth ExtractionSurgeryFemaleMolar ThirdOral SurgerybusinessPanoramic Radiographs
researchProduct

Ex vivo measurement reliability using two different cbct scanners for orthodontic purposes

2012

Background There are many cone beam computed tomography (CBCT) scanners available on the market: detector technology, algorithm precision, and scanner settings influence image quality. The aim of this study was to compare the accuracy of linear measurements made on images of the same sample obtained using two different CBCT scanners. Methods Twenty-eight linear measurements between orthodontic anatomical landmarks that were marked with gutta-percha points on a fresh sacrificed lamb head were taken three times. The head was scanned with two CBCT scanners using different scanning parameters. Digital Imaging and Communications in Medicine (DICOM) images were reconstructed and the same measurem…

ScannerCone beam computed tomographymedicine.medical_specialtybusiness.industryImage qualityDetectorSignificant differenceBiophysicsMeasurement reliabilityComputer Science ApplicationsDICOMmedicineCalipersSurgeryMedical physicsbusinessBiomedical engineeringThe International Journal of Medical Robotics and Computer Assisted Surgery
researchProduct

High accuracy Raman measurements using the Stokes and anti-Stokes lines

1997

We show that by measuring the separation between the Stokes and anti-Stokes peaks excited by two different laser lines we obtain a very precise determination of absolute phonon energies. The method is useful for measuring small changes of these energies with strain, temperature, laser power, etc. It doubles the changes and avoids the necessity of using the reference lines in the Raman spectra. The method can be applied for the determination of phonon deformation potentials, for the characterization of strained heteroepitaxial layers, and for micro-Raman analysis of strain in silicon integrated circuits. We give examples of phonon shifts in Si, Ge, GaAs, InAs, and GaP as a function of applie…

SiliconMaterials scienceSiliconRaman SpectraPhononAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_elementIndium CompoundsMolecular physicsGallium arsenidelaw.inventionGallium Arsenidesymbols.namesakechemistry.chemical_compoundThermo-Optical EffectsCondensed Matter::Materials Sciencelaw:FÍSICA [UNESCO]Laser power scalingSemiconductor Epitaxial LayersLaser Beam EffectsElemental SemiconductorsSilicon ; Germanium ; Elemental Semiconductors ; Gallium Arsenide ; Indium Compounds ; Gallium Compounds ; III-V Semiconductors ; Raman Spectra ; Phonon Spectra ; Semiconductor Epitaxial Layers ; Integrated Circuit Technology ; Deformation ; Laser Beam Effects ; Thermo-Optical EffectsGermaniumUNESCO::FÍSICAIII-V SemiconductorsPhonon SpectraLaserCondensed Matter::Mesoscopic Systems and Quantum Hall EffectIntegrated Circuit TechnologyDeformationchemistryExcited stateGallium CompoundssymbolsDeformation (engineering)Raman spectroscopy
researchProduct